Quantcast
Browsing all 16762 articles
Browse latest View live

Wind Tunnel Test Report

A wind tunnel test report is received from a client. The wind tunnel test procedure adheres to Austrailian Manual (AWES-QAM-1-2001), ASCE7-10 (Chapter C31), and CTBUH (2013) guidelines. The result of...

View Article


Image may be NSFW.
Clik here to view.

**** ERROR: Advanced Analysis is not supported

When I run my analisis that happens (see next one figure). Someone can help me?I sent you the file of my structurecommunities.bentley.com/.../2112.Structure_5F00_5.STD

View Article


Image may be NSFW.
Clik here to view.

How can I displaying Deflection Diagram in this case?

I have a model beam like a plate to obtain this discretization and I needed displaying all diagram.How ca I do this?Attach the file.communities.bentley.com/.../8741.Structure_5F00_5.STD

View Article

Image may be NSFW.
Clik here to view.

My staad file showing more warnings.I have attached my first,ground and...

View Article

Is the Learning Server Down ?

Hi, Im not able to access the learning server anymore please can you clarify what is the issue. ?

View Article


Wind Load Combination Factor

A wind tunnel test report is received from a client. The wind tunnel test procedure adheres to Austrailian Manual (AWES-QAM-1-2001), ASCE7-10 (Chapter C31), and CTBUH (2013) guidelines. The result of...

View Article

RAM Joint Code Check

I am able to perform the Joint Code Check for both the Standard and Seismic provisions in RAM Frame but am having issues with the reports.The joints will show up in the appropriate colors relative to...

View Article

Image may be NSFW.
Clik here to view.

I have inserted my ground ,first and basement floor plan and i have attached...

communities.bentley.com/.../0312.SAIF-BUILDING-MALIK.std

View Article


Staad Pro Lifting Analysis

Good afternoon. This is my first post. I'm doing a structural analysis for a lifting skid. The skid is large and narrow, with high loads on one side, so the COG is around 152in from one end. I'm...

View Article


how to release member through Excel Vba.

how to release member through Excel Vba. means if i have to give MX Mz release to member no 1 what will be the syntax similarly what will be the syntax for assign tension only member.

View Article

temprature load..

communities.bentley.com/.../LINK-BRIDGE-FOR-SUBMISSION.stdDear Sir,Ambient temprature change is 30 degree centigrade .kindly check applied temprature load is correct or not ???

View Article

How do I release a certain connection between two members without affecting...

Hi, I've got a member release problem that I am not sure how to manage.I have two members, 1 vertical post (CHS) and 1 horizontal member (PFC), the PFC is supporting the CHS in lateral forces only (Fx...

View Article

Revit Beam tag

Does anyone know of a beam tag that can access the information that imports from RAM Structural System? I would like to access the following in order to tag on plans: Beam Size, Top of Steel Elevation,...

View Article


EFT Command and Torsional Failure

Hi, I'm doing a lifting analysis of a stucture and the columns of the structure fail due to torsion (6.2.7(5)). Since, my beams were split i was trying to provide them EFT lengths, but when i do that....

View Article

Ram Connection Bolted Splice of vertical brace

I am using Staad Connect Edition with Ram Connections. I have a vertical brace that I want to splice like a column with bolted flange and web plates. I see in the troubleshooting post there is a way to...

View Article


Image may be NSFW.
Clik here to view.

Ram Steel composite beam: nonuniform loading

I am modeling a composite steel beam- concrete w/ metal deck system and several of the composite steel beam members are showing very strange increasing loading where the loading should be uniform. Can...

View Article

Image may be NSFW.
Clik here to view.

Limcon - Lacking of description of parameters for each type of connection

Hi Support Team when using Limcon there are many times I do not know exactly or completely sure what is the meaning of the input parameters for each type of connections.For example, in the single brace...

View Article


**ERROR** ELASTIC MODULUS (E) NOT ENTERED FOR MEMBER/ELEMENT/SOLID NO. 2

Sir I am New to Staad SSI 5 and while running a Truss model, i am getting the below error  **ERROR** ELASTIC MODULUS (E) NOT ENTERED FOR MEMBER/ELEMENT/SOLID NO. 2Pls help me in solve the same.

View Article

What is the problem here ? Floor Load Error !

I Have attached the staad file below. Please help.communities.bentley.com/.../HighRise-after-ground-prc.std

View Article

ly

https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/138355/want-to-count-the-effect-of-purlin-in-ped-steel-shed-design-with-out-draw-the-purlin-into-the-model/418819#418819Dear sir, As...

View Article
Browsing all 16762 articles