ISM Revit to RAM Joist Size Mapping

I have started using ISM so my company can have Revit/RAM interoperability. Currently using Revit 2018.2 with ISM plugin installed and Bentley's RAM Structural Enterprise suite. We have, for the most...

View Article


something is wrong in Buckling analysis for cantilever column

I am trying to check Bucking analysis results, so I modeled cantilever steel column with cross section I add to the Indian section library called “100CU82x2.7”, and I performed buckling analysis. I add...

View Article


Combined foundation design with STAAD.foundation

HiI am designing combined foundation with Staad.foundation V8i (ver 5.3) for pipe rack structure. I have open frame structure and most of the timethe stability checks ( Over turning and Sliding checks)...

View Article

RAM Concept Punching Shear Audit - At Corner Condition

Hello All,I have a situation where I am trying to validate the punching shear results from RAM Concept regarding a corner condition.  Could someone please explain, using the attached audit log, how one...

View Article

STAAD Advanced Foundations not meshing slab with piles

I have been trying to mesh a pile cap but I get an error that states that I need to contact service ticket manager which I will do.  I want Bentley to look into this error also because it is not doing...

View Article


STAAD Steel & Concrete Design Modules

Are the subject modules part of the standard STAAD.Pro functionality or does it require additional purchase?   These would be the tabs along the top of the product when in STAADThanks in Advance

View Article

Looking for clarification on RAM Steel Column Sign Conventions

Hello,I'm looking at this article, and would like some clarification:https://communities.bentley.com/products/ram-staad/w/structural_analysis_and_design__wiki/2055/ram-steel-columns-faThe diagram says...

View Article

Node Instability

Hi,When I run my STAAD model, I get a warning message that reads "warning - instability at joint 114 Direction = MX". The joint is within the catwalk framing and is at the intersection of the main...

View Article


Image may be NSFW.
Clik here to view.

STAAD output not showing reason of failure when designing using AISC 360-10

Staad Version: 20.07.10.41Track = 0Memory = 280(Structure is big, so cannot afford to modify the above parameters)As described above the reason of failure of some of the elements is not described. How...

View Article


request for Proforma Invoice

From: SUTRAVE Narendra /ENGINEERING MANAGEMENT/H.O. Sent: Thursday, November 09, 2017 12:02 PMTo:'bac@bentley.com'Subject: please provide PROFORMA INVOICE I am interested to purchase a latest version...

View Article

Beam Failure

Hi -I ran my Staad model and had it check all the members against AISC code.  Beam 256 is unexpectedly failing.  I'm not sure if it's due to an improper connection to another member.  Can someone...

View Article

Latest version of #Limcon

Hi May I knowwhat's the latest version of LimconDoes it support the latest codes, such as AISC360-16 and CSA S16-14Any new featureKind RegardsOliver

View Article

Update header in report to not say Demo User?

Hi Abhishek !Problem solved, butin the header in the report it is a text with small letters that says that I am a Demo user ???We would like to remove the text.Regards Tore

View Article


Connection Client - Where is it?

We are a small firm with three users and two licenses.  I am informed that we must register each user on the computer they are using.  There is no link to the Connection Client software that is...

View Article

Image may be NSFW.
Clik here to view.

Skewed beams not picking up load from slab

I have a slab edge following a skewed angle. The slab distributes load to the member running perpendicular to the deck span but not to the skewed beam. Is this a glitch or are there special techniques...

View Article


Meaning of WARNING

What is the meaning of  "WARNING, 1 or more joints are in multiple SUPPORT commands, First Joint   938  The subsequent entries will add to support direction specs." ? How can it be avoided?

View Article

Ram Connection and International codes

Does Ram Connection support BS EN 1993-1-1:2005, AS 4100-1998, CSA S16-14 and  now? If not, when is it going to support thees codes?

View Article


RAM Concept - Imported CAD file not showing all layers

I'm trying to import a CAD file into RAM Concept however its not showing the layer where displays the wall loads. I've tried to create this as a new layer and also tried to save the DWG as a AutoCAD...

View Article

How to get reinforcement details of bridge structure after analysis in staad...

I think the goal of a design is to get reinforcement of a concrete bridge structure but how can i get reinforcement details after analysis in staad pro? 

View Article

How does staad take into account the effect of reinforcement of concrete...

When we model a RCC structure,  it is pure concrete without steel reinforcement defined, so how does staad take into account the effect of reinforcement during analysis? 

View Article