Quantcast
Browsing all 16762 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

Cant use indian code

Though the license are activated ,I cant use it while adding parameters for indian concrete code.What might be the problem.I have tried reinstalling but it didnt help

View Article


Image may be NSFW.
Clik here to view.

How to add stiffeners in C section beam for IS 800 LSD code/ IS 800?

I want to add stiffener in the beam (Custom C section) and i am using IS 800 LSD code for the analysis. How to do? Which parameter is used for that in Indian code? I have also attached image for the...

View Article


Image may be NSFW.
Clik here to view.

StaadPro_Floor Load_One Way Distribution

HiIn the StaadPro S6 version 20.07.11.82, when you define a Floor Load with One way distribution towards a selected beam, and the visualization of the load applied is incorrect if you open and save the...

View Article

TORSION GOVERNING FOR TUBE SECTION

HiI am using tube sections in staad and have found, that the utilization is much lower with the setting: "TORSION 3 ALL"The beam is cantilever, main loading is bending, the shear and torsion is below...

View Article

Difference between wall with openings and individual walls

I have 2 models of the same structure in which the core lateral system is comprised of shear walls with openings of various sizes (doorways and openings for operable partitions [OP]). One version of...

View Article


Positive Moment at Pinned Support - RAM SS Concrete

I am modeling a concrete building, and I have a simple span beam between two girders that is pinned at both ends (pinned in Major and Minor Axes, fixed in Torsion). What would the reason be for this...

View Article

gibberish tags

I'm using this post to track down and delete some gibberish tags on our site. No reply needed.

View Article

Design codes issue in STAAD.Pro

Hello support,If I want to use the design code BS EN 1993-1-1: 2005 , which code pack should I buy?Can I use it if i have the UK Super code license only?Please help. Thanks in advance. 

View Article


what are the checks to be performed while designing steel members

i have designed the steel truss along with columns but i (Please visit the site to view this file)wants to know what are the checks to be performed further while designing steel members. staad file...

View Article


How to assign section properties to SOLID Elements?

I am just wondering how to assign properties to solid elements. Please help

View Article

Cracked Properties for shear walls

Good Day everyone,How can I account for the ACI code prescribed cracked sections in surface elements in STAAD Pro, such as a shear wall?

View Article

modelling floor slabs - how to proceed

Good evening,my student colleagues and I have been set a question the issue is we disagree with the lecturer on how to proceedThe question was“A rectangular solid concrete flat slab floor, with a...

View Article

detailed calculation output conforming to AS4100

How can I get detail "design calculation output for a steel member "conforming to AS4100 code using staadpro SS6

View Article


Image may be NSFW.
Clik here to view.

Error - SUPPORT OR SPRING IN SLAVE DIRECTION

HelloJust like a prior poster I am getting a SUPPORT OR SPRING IN SLAVE DIRECTION error when resolving a structure.  My structure is a plate slab on a beam grid joined at nodes by slave master nodes...

View Article

Example Manual

How can i get the example manual for STAAD.Pro V8i??

View Article


How to display total weight of structure in staad pro? my model is concrete...

Sorry, can somebody tell me how to display the total weight of my structure... and can you tell me why lateral load in support reaction is so big. thanks(Please visit the site to view this file)

View Article

Effective Length verification

How to verify the effective length of the column after analysis for a steel member?If a cantilever beam having effective length 2L how can i validate the result of the member that it takes the...

View Article


Which Mode is Batter For RCC deisgn

Dear sir,I design a 12 storied R.C.C structure.After analysis the structure the batch mode result and  iterative R.C design mode result is vary. please tell me which mood is batter for R.C.C design.How...

View Article

Is there any way to remove Beam release specification from specified beam...

Is there any way to remove releases from specified beam using OpenStaad?

View Article

Staad Foundations

Hello,I am using Staad foundations for the first time.  I built a model of a Mat supported on piles and created load combinations.When I click on "Edit current Job"  I see my 32 load combinations in...

View Article
Browsing all 16762 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>