How to find Approx. concrete & steel quantity from Output file.
communities.bentley.com/.../Stallion_2800_04_2D00_04_2D00_18_29002D00_1_2800_-FOR-BOQ--_2900_.STDDear sir,How to find Approx. concrete & steel quantity from Output file.initial I got in output...
View ArticleHOW TO DESIGN SLOTTED HOLES IN BASE PLATE TO AVOID HIGH TEMPERATURE FORCES
Dear All,Please advise me how to avoid high reaction force due to temperature load by considering slotted holes. also advise whether my seismic & wind definition/loads considered are...
View ArticlePost processing units change
Hello,I have selected base units metric, units for the file are mm & kg (same appears in the input file"STAAD Editor").When i go to postprocessing mode after analysis, I find units for the moments...
View Articleproperties not visible
Ever since STAAD Connect Edition was released (currently experiencing 21.00.01.12), I am unable to find any option that turns on the properties name as it used to be. Great work have been put into the...
View ArticleIssues with the latest STAAD Pro connect edition
Dear all, I'm currently using the newly released edition of STAAD Pro Connect Edition. However, I'm facing certain issues with this software1) When we manually edit some data in the Command...
View ArticleSTAAD(X).Tower Eurocode development release date
Has the planned STAAD(X).Tower Eurocode development been released? I had been advised it was due 31st March.
View ArticleBase Plate design- STAAD.Pro CONNECT Edition
Hi there,Staad Pro version- STAAD.Pro CONNECT EditionI have a Built up column section made from two W12x16 spaced at 18" and 1/4" thick plates. Plates are welded to flanges.It forms a sort of...
View ArticleRAM Elements applicable code design
I am trying to design sheet piles for combined loadings. I created a section based on an aisiFurring strip since that is the closest shape to sheet piles. I specified A992 gr 50 steel. When I run a...
View ArticleRAM Connection 12
I found RAM Connection 12 available on the select downloads page - my connection client has been trying to serve me V11.2 for 6 months now even though I had it installed for 6 months. Anyways, are...
View ArticleSTAAD Post Design Check
Hello,Can anyone verify my model and design which I have analyzed and designed using staad pro.?I have designed it for Ground floor only with the help of an AutoCAD plan.I have not used any load...
View ArticleCan someone tell me the error in the following staad code. For background -...
STAAD SPACESTART JOB INFORMATIONENGINEER DATE 04-Apr-18END JOB INFORMATIONINPUT WIDTH 79UNIT FEET KIPJOINT COORDINATES1 0 0 0; 2 1.67 0 0; 3 19.66 0 0; 4 21.33 0 0; 5 1.67 -6.5 0; 6 19.66 -6.5 0;7 0.29...
View ArticleDirect Analysis Method Help
Hello,This is a 2-part question.First: I have tried to set-up the direct analysis method in the attached model. I ran the model ASD and added in LRFD combinations at the end to use for the direct...
View ArticleInverted Beam and offset Slabs in RSS
Hi everyone,I would like to know if it is possible to model inverted beam or to apply an offset in a slab in RAMThanks.Gustavo
View ArticleCrack width in RAM
Dear RAM Team,is it possible to check the crack width in RSS? ThanksGustavo
View ArticleIam a new user of Staad Pro. Got an error message ''zero length detected''...
communities.bentley.com/.../3364.Str1.std
View ArticleRAM Concept - Design Envelope
How can I determine which load combination relates to a specific design envelope?
View ArticleBug "unstressed LENGTH" in cable specification
Hello,I noticed a bug about the specifiction of the "unstressed length" for cables. When I type a value of 2.1m or 2.2m for example, the software crashes. It works for 2m and 2.25m, but between these...
View ArticleWarning: Moment amplification factors
Hi,Can you please tell me what is warning: The value of moment amplification factors Ky or Kz is greater than 1.4? What do we do when we have this warning?Thank you
View ArticleMoment at Pinned Connection
Hello Everyone,I am trying to model a bridge deck and girders. It is a simply supported span, however the moment is not equal to zero at the supports. Also, all the beams look like they are deflecting...
View ArticleSolids and Plate Elements Load Transfer
communities.bentley.com/.../Wind_5F00_Turbine_5F00_Footing_5F00_Design_5F002D005F00_page_5F00_6.pdfI have come across the attached PDF after looking for some information on this topic.In the PDF, solid...
View Article