Hi,
I have done FEM of L shape raft and provided sping support by assining foundation-plate mat, Direction - Y, Subgrage - 600000 kN/m2 & generate com. only/multi-linear spring-compression only. But my Raft is unsatble in Mz at 1 node.
pl. help
Regards