Just FYI, when you run a design on a structure that uses open-web steel joists in RAM Elements 13.4.0.164, you may get a status message like the screenshot below indicating that Elements has designed the joists to a different design method than what was selected. In my case, the structure was designed for AISC ASD 2010, and it said the joists were being design for 2005 LRFD. This appears to be only a reporting typo. The allowable loads in the steel joist report matched the SJI ASD load tables, not the higher LRFD tables, in my case anyway. Thanks.