Viewing Design UR (Code Check) Results Graphically when more than one Design Parameter set is used

$
0
0

I have set up an analysis model with two sets of design code checks for each member, 1) with RATIO = 1.0 for a given LOAD LIST, and 2) with RATIO = 1.33 for a different LOAD LIST.

When I view the design results graphically, it only seems to show the UR based on 2nd set of design parameters. See extract below.

Can I make adjustments in the graphical display so that I can toggle between the two sets of data, i.e. to see UR in each case?

***NEW STEELWORK CODE CHECKS - OPE CASES

LOADLIST9TO18

PARAMETER1

CODEAISCUNIFIED2010

METHODASD

RATIO1MEMB _NEW_STEEL_DESIGN

CHECKCODEMEMB _NEW_STEEL_DESIGN

***NEW STEELWORK CODE CHECKS - STORM CASES

LOADLIST19TO22

PARAMETER2

CODEAISCUNIFIED2010

METHODASD

RATIO 1.33 MEMB _NEW_STEEL_DESIGN

CHECKCODEMEMB _NEW_STEEL_DESIGN

 