P-Delta Analysis on structures supported on Soil

$
0
0

*I am running P-Delta Analysis on a reinforced concrete tank

PDELTA ANALYSIS CONVERGE 2 SMALLDELTA

*The bottom of the tank is supported on soil and I am using foundation support as follows:

SUPPORTS
2578 TO 3393 PLATE MAT DIRECT Y SUBGRADE 31 PRINT COMPRESSION

*The analysis gives my many warnings about instability which I am assuming though to Compression only support definition (see above line).  

*so I went ahead and changed the support definition to get rid of compression only as follows:

SUPPORTS
2578 TO 3393 PLATE MAT DIRECT Y SUBGRADE 31 PRINT

*I then ran the P-Delta analysis and all the warnings went away. 

*Question is: Compression only supports do not work with P-Delta analysis? 

*Using the normal "PERFORM ANALYSIS" does not give me any warning with the following: 

SUPPORTS
2578 TO 3393 PLATE MAT DIRECT Y SUBGRADE 31 PRINT COMPRESSION

Thank You in advance. 