RAM Concept - Mat Slab on grade - Reinforcement

I'm working on a mat slab on grade to support a silo at a concrete batch plant and wanted to model the slab in RAM Concept.

1. Our model for a slab on grade has flagged ACI318 section 7.12.  Per ACI318 section R7.12.1, this section is not for slabs-on-grade.  Why does RAM Concept check temperature and shrinkage reinforcement for a mat slab on grade, and is there a way to turn off this check?

2. Is there a way to change RAM's program assigned distributed reinforcement default output from number of bars to a bar spacing (without changing to user defined bar spacing)?

3. Is there a way to view/output the formulas and calculations (for a report), similar to RAM Connection's reports? 