hi,

There is a RAM software problem about different size column cover plate splice connection. In bolted cover plate cs(non-bearing) connection for different size, when we click the "consider interior plate", why the bolt shear capacity doesn't multiply 2, it should be *2, we can put a packing plate there, can you explain that is why?

now, we use the BS EN 1993-1-8:2003.

Here attach the related formula about bolt shear capacity or the RAM file

.

b:  Plate width                                                                        :           300 mm

            Consider interior plate                                                 :           yes

            Material                                                                       :           Q345

            tp:  Thickness                                                            :           14 mm

            Bolts                                                                            :           M24 G_8_8

            Hole type on column                                                   :           STD

        Flange cover plate

            Bolt group shear                                                         [KN]                  877.28           1271.13    case3           1.45     pt. 1-8 Table 3.4

           Fv,Rd = (av*fub*A)/gM2 = (0.6*800[N/mm2]*353[mm2])/1.25 = 135.55[kN]                                                             pt. 1-8 Table 3.4