Hi there,
When I create a 3D model in ram structural system, apply loads, analyse and obtain transfer loads/reactions out of the RAM concept file (from within structural systems), the reactions values are different to when I create a 2D model in RAM Concept alone. I have checked applied loads, ensured analysis codes are the same and checked mesh inputs correlate.
Is there a difference between RAM concept and RAM Structural Systems when it comes to load paths that could be responsible for this?
I would have thought if the mesh and loads are identical, reactions should be the same in theory.