User Defined Story Forces (RAM SS) into RAM Connection?

$
0
0

I have a RAM Structural System model that I have manually inputted my wind forces with "User Defined Story Forces" for a "Type-Wind" load cases.

After analysis of RAM Frame, including member and code checks, I have tried to used the RAM Connection for some base plates design checks. Within RAM Connection all the load case and load combinations are visible in the software. One wind nodal load case was also brought over from RAM SS. Even thought all the load cases are visible, none of the generated load combinations from RAM SS are editable in RAM Connection platform. 

Investigating one base plate design, the "Loads" in the RAM Connection Pad only show analysis being performed from the gravity load cases, one nodal wind load, and the generated load combination for those load cases only.  NONE of the generated load combinations that included the "user defined story forces" load cases from RAM SS were included in the base plate checks?

How do I get these load reactions included in my base plate? 