Morning All,
I am attempting to design shear wall to AS 3600 in RAM Concrete and I keep getting an error message which states "Unspecified error" with the title bar stating "WallAS3600" (see screenshot). When I close the error, I get the RAM Contained MFC Application has stopped working dialogue which prompts me to close so I cannot trouble shoot which wall is being designed when the error initializes. I have tried deleting section cuts in RAM Frame and align walls as per other past posts on similar topics but I could not find anything on this exact error. I have gone back and deleted Wall Design Group 2 and it gets up to Wall Design Group 5, Section Cut SC5H:23A when I get the error message again. I have looked through the model and there appears to be a number of section cuts with duplicate names. I have done the obvious and cleared and regenerated the section cuts but with the same result. Any thoughts on what the cause of this might be?
Anthony