NA check & torsion value not appearing in output value

$
0
0

While designing according to eurocode i have used NA2 in design parameters 

But in STAAD o/p file it only show:

ADDITIONAL CHECKS AS PER NATIONAL ANNEX [NEN-EN 1993-1-1/NB] (units- kN,m):

EC CLAUSE NA-CLAUSE RATIO LOAD FX VY VZ MZ MY

but no values appear.

While using TOR 2 parameter 

In post processing MX represent value of torsion on particular member

but In STAAD o/p file under additional torsional checks MX value appears 0.0 for all members in spite of MX value in post processing mode.

Lets say for member 27 

max value of MX  in post processing is 0.126kN,m (i.e.,12.874kg.m)

But in STAAD o/p file

TORSION CALCULATIONS (units - kN,m)
Total Torsional Load T = 0.0
Effective Length for Torsion = 0.188
END1: Torsion Fixed, Warping Fixed END2: Torsion Fixed, Warping Fixed

Max. section forces & capacities: [@ x = 0.000](units - kN,m)
Torsion at section = 0.0
Pure Torsion Component = 0.0
Warping Torsion Component = 0.0

One more que can we change unit of results in STAAD o/p file?