While designing according to eurocode i have used NA2 in design parameters
But in STAAD o/p file it only show:
ADDITIONAL CHECKS AS PER NATIONAL ANNEX [NEN-EN 1993-1-1/NB] (units- kN,m):
EC CLAUSE NA-CLAUSE RATIO LOAD FX VY VZ MZ MY
but no values appear.
While using TOR 2 parameter
In post processing MX represent value of torsion on particular member
but In STAAD o/p file under additional torsional checks MX value appears 0.0 for all members in spite of MX value in post processing mode.
Lets say for member 27
max value of MX in post processing is 0.126kN,m (i.e.,12.874kg.m)
But in STAAD o/p file
TORSION CALCULATIONS (units - kN,m)
Total Torsional Load T = 0.0
Effective Length for Torsion = 0.188
END1: Torsion Fixed, Warping Fixed END2: Torsion Fixed, Warping Fixed
Max. section forces & capacities: [@ x = 0.000](units - kN,m)
Torsion at section = 0.0
Pure Torsion Component = 0.0
Warping Torsion Component = 0.0
One more que can we change unit of results in STAAD o/p file?
I am attaching STAAD file here
(Please visit the site to view this file)